Page 42 - NYRKOVA_AREF
P. 42

40


               In the dissertation work, a scientific and applied problem is solved – the regularities
        of  corrosion  cracking of steel of  main gas pipelines  under their cathodic  protection  are
        established, the solution of which expands the understanding of the mechanism of stress
        corrosion  cracking  of  main  gas  pipelines,  which  makes  it  possible  to  scientifically
        substantiate approaches to the choice of methods for its prevention.
               The  methodology  for  assessment  the  susceptibility  of  steel  X70  to  CC  under
        cathodic  protection  conditions  has  been  scientifically  substantiated,  a  coefficient  of
        susceptibility  to  CC  K   in  which  the  changing  of  plastic  properties  of  metal  in  the
                                    S
        corrosive environment in comparison with its properties in air was takes into account been
        offered.  An  assessment  criteria  of  susceptibility  of  pipe  steel  to  CC  was  introduced:  if
         K      6 , 1  steel is susceptible to CC, which confirmed by the results of laboratory and field
           S
        studies.  A  complex  of  factors  which  are  causing  the  degradation of  protective  polymer
        coatings  (in  particular,  polymer  tape  coating),  namely  the  presence  of  a  defect  in  the
        coating, its contact with a corrosive medium and cathodic polarization was revealed. By
        the method infrared spectroscopy the degradation of the primer layer of the polymer tape
        coating  was  confirmed  and  it  was  proved  that  the  presence  of  degradation  products  of
        polymer tape coating in the solution increases the susceptibility of pipe steel to CC:  K
                                                                                                             S
        increases from 1,7 in the solution in which polymer coating was not in contact to 2,63

        in the solution after contact with the cover. Under conditions of long-term operation at
        constant  deformation  in  the  model  soil  electrolyte  at  a  potential  close  to  the  maximum
        protective -1,0 V, for X70 steel is more susceptible to subsurface corrosion, and for X80 –
        intergranular fracture caused by hydrogen.
               For steels of different strength level, a new method for assessment of their tendency
        to CC was proposed, based on the analysis of the length of the descending sections of the
        fracture curves, and the corresponding coefficient K  is introduced. It was established that
                                                                   τ
        at  the  temperature  50  C  the  properties  of  the  steel  substrate  make  the  effect  on  the
                                   о
        cathodic disbondment of polymer coatings: on steel X80, the disbondment process of the
        coating  proceeds  more  intensively  than  on  X70,  which  is  due  to  decreasing  in  the
        hydrogen evolution potential on steel X80 and the structure of the near-surface layer.
               It has been experimentally proven that three potential regions exists in which the CC
        of X70 steel proceeds according to different mechanisms: at potentials more positive than
        -0,75  V  –  by  the  mechanism  of  local  anodic  dissolution,  in  the  potential  range  from
        -0,75 V to -1,05 V, a mixed mechanism of CC acts (local anodic dissolution and hydrogen
        embrittlement occur simultaneously), at potentials more negative than  -1,05 V – by the
        mechanism  of  hydrogen  embrittlement.  The  regularities  of  CC  are  confirmed  by  the
        changing in the corrosion-mechanical properties of steel, estimated by the coefficient K ,
                                                                                                            S
        and  by  fractographic  signs  of  destruction.  Decreasing  of  the  cathodic  potential  to  the
        minimum protective potential -0,75 V (c.s.e.) provides the preservation of the protective
        properties  of  polymer  coatings:  new  and  artificially  aged  tape  coating  –  by  9,4  and

        26,9 times, respectively; new hybrid-epoxy coating – by 3,3 times, artificially aged – by
        1,7 times;  new and artificially aged polyurethane coating – by 20 times.
               A  methodology  for  identifying  of  potentially  corrosive  dangerous  areas  of  gas
        pipelines under cathodic protection was developed and implemented which is based on the
        calculation of the probability of corrosion cracking using on the data of design, executive,